Electro-Acoustic

Electro-acoustics covers the design, specification and commissioning of sound reinforcement and voice alarm systems within buildings and venues. Poor system design leads to uneven coverage, unclear announcements and non-compliance with emergency sound standards — all of which are avoidable with proper acoustic modelling before installation. From entertainment venues to commercial offices, every system is designed to deliver clear, intelligible sound across the entire space.

Standards that shape sound insulation design

Speech Intelligibility

Every system is modelled and tuned to meet STI thresholds, so announcements and spoken word remain clear and understandable throughout the space.

3D Acoustic Modelling

Predictive modelling identifies coverage gaps, reflections and dead spots before any speaker or amplifier is installed, reducing the risk of costly rework.

BS EN 60849 Compliance

Voice alarm systems are designed and verified against the British and European standard for emergency sound systems, satisfying fire authority and building control requirements.

System Commissioning

On-site verification confirms that real-world speech intelligibility and sound coverage match the original design targets before handover.

Our areas of expertise

Commissioning & Verification

Post-construction acoustic commissioning and verification confirms that completed buildings and installed systems achieve their specified performance targets and satisfy planning conditions, BREEAM requirements and client acceptance criteria.

Sound System Design

Sound reinforcement and distributed audio system design for hospitality, leisure, retail and performing arts venues specifies loudspeaker layouts and system parameters to achieve the coverage uniformity, intelligibility and tonal quality required for the intended use.

Venue & Auditorium Design

Acoustic design for entertainment venues, performance spaces, theatres, nightclubs and bars addresses both the internal acoustic quality and the noise breakout performance required to satisfy planning conditions, licensing authorities and neighbouring receptors.

System Optimisation and Tuning

Measurement-led optimisation of installed sound systems corrects equalisation, delay alignment and level distribution to achieve the coverage uniformity and tonal balance the original design intended and the operator's programme requires.

Sound Limiter

Sound limiter specification and commissioning establishes the highest operating level that keeps amplified music within planning conditions and Environmental Health criteria, without making the venue acoustically unworkable for operators and performers.

Case Studies for

Electro-Acoustic

We handle the technical work so your space performs as intended. Our team brings decades of combined experience to every project, whether it's a restaurant needing clarity or a building requiring acoustic control. Each solution is engineered with precision and delivered with care. solutions built on precision, delivered with expertise, proven through results.

Antalya Restaurant

Performance venue
Reverberation control
Sound isolation

We have designed acoustic solutions for demanding environments across multiple industries. Each project taught us something about the relationship between sound, space, and human experience.

Suleymaniye Mosque London

Performance venue
Reverberation control
Sound isolation

This project highlights how early acoustic involvement can help unlock planning approvals for sensitive developments. By combining technical expertise with planning knowledge, EMC Acoustics helped deliver a practical and successful solution in a challenging urban setting

Gallipoli Restaurant

Performance venue
Reverberation control
Sound isolation

We have designed acoustic solutions for demanding environments across multiple industries. Each project taught us something about the relationship between sound, space, and human experience.

Questions

Find answers to common questions about our acoustic services and process.

When should I hire an acoustician?

Early in the design phase, before construction decisions are locked in. Acoustic problems are hardest and most expensive to fix after the fact. We help you avoid costly mistakes by addressing sound quality from the start.

What standards do you follow?

We design to relevant British and international standards including BS 8233, ISO 3382, and BS EN 60849. Standards vary by building type and use, and we select the right ones for your project.

How long does a typical project take?

Timeline depends on project scope. A small office assessment might take weeks. A large venue design can span months. We work within your construction schedule and provide clear milestones at each phase.

Can you improve an existing space?

Yes. We assess what's wrong, test solutions, and recommend treatments that fit your budget and constraints. Retrofits are often more complex than new design, but improvements are usually achievable.

Do you handle compliance testing?

We measure and verify that completed spaces meet design targets and regulatory requirements. Post-construction testing confirms the work was done right and gives you documented proof of compliance.

More questions?

Reach out and we'll discuss your acoustic needs.

Make the Right Acoustic Decisions for Your Space

Contact our team today for a consultation tailored
to your specific needs and requirements.